Sign In | Join Free | My portofva.com |
|
Brand Name : SINOMATIC
Model Number : LD-600
Certification : CE/ ISO
Place of Origin : Shenzhen, China.
MOQ : Sample order accepted
Price : negotiable
Payment Terms : T/T, L/C, D/A, D/P, Western Union, MoneyGram
Supply Ability : 3,0000pcs per month
Delivery Time : 2-5 working days after payment received
Packaging Details : Carton/Plywood box/Pallet
Model : LD-600
Output relays : 240V/5A
Warranty : 1 year
Power consumption : less than 5W
Loop connection wiring : Maximum length 200 meters Twisted at least 20 times per meter
Output : 4 relays
LD -600 Traffic Loop Detector With 4 Relays In Parking Management System
Introduction:
LD-600 is used for wherever vehicles have to be detected, for example for monitoring and safe-guarding access ways or for counting vehicles. The output signal can be used for controlling door drive mechanisms, operating barriers, activating card dispensers etc.
Installing the loop :
After determining the loop geometry, a groove (5-8 mm wide, 30-50 mm deep) must be cut in the floor for installing the loop. We recommend cutting an inclined groove (45° angle) at the corners of the loop. Routing the loop wire along this incline will protect it from excessive wear at the corners. The groove must then be cleaned avoiding any kind of moisture. Run the loop wire as tight as possible along the very bottom of the groove.
You can use commercial copper strand (flexible, insulated, 1.5 mm)
A.Application Scope :
A1)Parking lot entrances vehicle detection ;
A2)Parking lot space information acquisition system ;
A3)Electronic police traffic lights snap shot system ;
A4)Traffic monitoring system .
B.Main Characteristics:
Type:TLD-600(double channel)
Operating temp.: -30°C ~ +75°C
Storage temp.: -40°C ~ +85°C
Relative humidity: ≤95%
Shell: PC + ABS engineering plastics
Installation: DIN rail
Dimensions: 110×60×100 mm (L×W×H)
Net Weight: 400g
Operating voltages:AC220V±10%
Power consumption:<5W
Relay output:DC24V /3A
Frequency range:20kHz ~ 170kHz
Reaction time:10 ms
Sensitivity:10 grades adjustable
Loop inductance: Ideal 100µH~300µH Max 50µH~1000µH
Product diaplay:
Product flow and package:
![]() |
LD -600 Traffic Loop Detector With 4 Relays In Parking Management System Images |